Product TB-M18-H1147/C53
HF Read/Write Head
For Bus Line Topology with TBEN-*
Order number: 7030729- Threaded barrel, M18 x 1
- Chrome-plated brass
- Device without end termination
- Device may only be operated in line topology TBEN-S*-2RFID-* or TBEN-L*-4RFID-*
- Max. 32 nodes per line or connection permitted
- Use a corresponding terminating resistor (see accessories)
- Observe the performance of the power supply, especially when turned on, and the maximum current carrying capacity of the cables
- Observe the voltage drop on the line
- The maximum possible length of the spur line is 2 m
- The maximum possible length of the bus is 50 m
- By default, a command can only be processed by one read/write head, making HF bus mode suitable for static applications and slow dynamic applications
- In continuous HF bus mode, a command is executed simultaneously on all read/write heads in a bus topology. The recorded data is stored in the ring buffer of the module
- The read/write head is automatically assigned an address
- For different application requirements, the address and can be parameterized
- Powered and operated only via connection to BL ident interface module
- Electrical connection only via BL ident extension cable

Data Sheets
| German | 544 KB |
| English | 543 KB |
| French | 544 KB |
| Spanish | 600 KB |
| Czech | 546 KB |
| Dutch | 543 KB |
| Romanian | 544 KB |
| Russian | 800 KB |
| Polish | 546 KB |
| Chinese | 670 KB |
| Turkish | 545 KB |
Calculation Tool for HF Bus Mode
Configuration Manual
Configuration Software
Firmware
Manufacturer's Declaration
Product Flyer
Quick Start Guide
Mounting accessories
|
WKC4.5T-12/TXL | 6631634 |